Bolt Length For Unistrut

Judge dredd origins cbr torrent kickass

Each section of Unistrut channel has four dimension attributes: length, width, height, and wall thickness. Out of these variables, length is probably the easiest place to start. The vast majority of Unistrut channel sections come in 10’ and 20’ lengths. There's no need for additional fasteners with these nuts— they combine a strut channel nut with a spring and a threaded stud. Twist-In Strut Channel Nuts When there's no access to the open side of a strut channel, slip one of these nuts through a slotted hole and turn it 90° to secure it in the channel.

One of the most common requests we receive concerns drawings for Unistrut support structures.

The tables below contain downloadable standard design detail drawings for typical Unistrut applications–medical supports, rooftop walkways, and ceiling grid systems.

Please Note: Drawings below are generic details to show design intent only. The drawings will help you gain a better understanding of engineered system design options, but these drawings are not intended for construction purposes because each system is application specific. We are currently working on developing additional standard details for other systems, but at this time, we only offer resources to support the development of medical supports, rooftop walkways, and ceiling grid structures.

For interior applications, rooms will more than likely contain suspended MEP and we may need to make modifications to an existing design to accommodate mechanical systems such as plumbing, HVAC, and electrical. Contact Unistrut Service Company for pricing on site specific engineered system drawings.

Medical Support Structure Standard Detail Drawings

Unistrut Spring Nuts And Bolts

Bolt Length For Unistrut

The tables below contain downloadable standard design detail drawings for typical Unistrut medical support structure applications. Fleetwood prowler manuals.

Please Note: Drawings below are generic details to show design intent only. The drawings will help you gain a better understanding of engineered medical support structure design, but they are not intended for construction purposes because each system is application specific.

*Unistrut Cath Lab Support Structure Standard Detail Drawings
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.
** There are no standard details for Cath Lab Supports attached to bar joists as bar joists are typically insufficient to handle the load.
Concrete Applications**Steel Beam Applications
Concrete BeamsConcrete With Metal DeckWide Flange Beam Structure
Ceiling Rails
Parallel to Beams
DWG
Ceiling Rails
Parallel to Metal Deck
DWG
Ceiling Rails
Parallel to Beams
DWG
Ceiling Rails Perpendicular to Beams
DWG
Ceiling Rails Perpendicular to Metal Deck
DWG
Ceiling Rails Perpendicular to Beams
DWG
*Unistrut Exam Light Support Structure Standard Detail Drawings
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.
Joist ApplicationsConcrete Applications
Bar Joist Structure
DWG
Concrete Beams
DWG
Flat Concrete Deck
DWG
Concrete With Metal Deck
DWG
*Unistrut Three and Four Rail Support Structures
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.
Joist ApplicationsConcrete Applications
Three Rail Bar Joist Structure
NA
Three Rail Concrete Deck Support Structure
DWG
Four Rail Bar Joist Structure
DWG
Four Rail Concrete Deck Support Stucture
DWG
*Unistrut Injector, Monitor, and Surgical Light Support Structures
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.
Joist ApplicationsConcrete Applications
Bar Joist Structure
DWG
Concrete Beams
DWG
Flat Concrete Deck
DWG
Concrete With Metal Deck
DWG
Bolt Length For Unistrut

Rooftop Walkway Standard Detail Drawings

The tables below contain downloadable standard design detail drawings for typical Unistrut rooftop walkway applications.

Bolt Length For Unistrut

Please Note: Drawings below are generic details to show design intent only. The drawings will help you gain a better understanding of engineered rooftop walkway design, but they are not intended for construction purposes because each system is application specific.

Bolt Length For Unistrut

Your rooftop walkway system will likely include sections that are less than 10′ in length, and we may need to make modifications to an existing design to accommodate mechanical systems such as rooftop HVAC units, vent stacks, etc. Contact Unistrut Service Company for pricing on site specific engineered system drawings.

Unistrut Rooftop Walkway Standard Detail Drawings
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.
DescriptionLength.DWG.PDF
One Handrail, Grating Parallel to Seam10'Download DWGDownload PDF
One Handrail, Grating Perpendicular to Seam10'Download DWGDownload PDF
Two Handrails, Grating Parallel to Seam10'Download DWGDownload PDF
Two Handrails, Grating Perpendicular to Seam10'Download DWGDownload PDF
No Handrail, Grating Parallel to Seam10'Download DWGDownload PDF
No Handrail, Grating Perpendicular To Roof10'Download DWGDownload PDF
One Handrail, Flat Roof Application10'Download DWGDownload PDF
Two Handrails, Flat Roof Application10'Download DWGDownload PDF
No Handrail, Flat Roof Application10'Download DWGDownload PDF

Unistrut Ceiling Grid Standard Detail Drawings

The tables below contain downloadable standard design detail drawings for typical Unistrut ceiling grid applications.

Please Note: Drawings below are generic details to show design intent only. The drawings will help you gain a better understanding of engineered ceiling grid design, but they are not intended for construction purposes because each system is application specific.

Unistrut Standard Detail 4' x 4' Grid Section Drawings*
ApplicationCorner ConnectionsDuty Rating.DWG.PDF
Concrete DeckSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Concrete DeckTwo Plane Lapped GridStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Concrete Deck /Corrugated MetalSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Concrete Deck /Corrugated MetalTwo Plane Lapped GridStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Beams/JoistSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Beams/JoistTwo Plane Lapped GridStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.

Unistrut Nuts And Bolts

Unistrut Standard Detail 6' x 6' Grid Section Drawings*
ApplicationCorner ConnectionsDuty Rating.DWG.PDF
Concrete DeckSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Concrete DeckTwo Plane Lapped GridHeavy DutyDownload DWGDownload PDF
Concrete Deck /Corrugated MetalSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Concrete Deck /Corrugated MetalTwo Plane Lapped GridHeavy DutyDownload DWGDownload PDF
Beams/JoistSingle PlaneStandard DutyDownload DWGDownload PDF
Heavy DutyDownload DWGDownload PDF
Beams/JoistTwo Plane Lapped GridHeavy DutyDownload DWGDownload PDF
*Drawings are generic details to show design intent only. Contact Unistrut Service Company for pricing on site specific drawings.

Bolt Length For Unistrut Clamps

United Interlock Grating is engineered with a strength-to-weight ratio that allows it to withstand substantial loads while being easy to handle. The male-female legs of the roll-formed grating interlock securely, and double-male legs provide a safe finished edge for end planks.
Two standard surfaces are available: slottedsmooth and anti-skid. Anti-skid is the ideal choice when safe walking conditions are important. Dieformed teeth in the transverse ribs give you 360° of shoe-gripping traction even when the grating is wet, oily, muddy, or icy.
Punched Interlock Grating has an open area of 42% for 9' grating and 35% for 6' grating. This prevents dirt, debris, ice, and snow from building up on the surface and allows light and air to pass through. United Interlock steel grating is made from pre-galvanized steel which conforms to a G-90 thickness designation per ASTM A653. The aluminum grating is made from type 5052 aluminum with a thickness of 0.080'.
Unpunched smooth surface grating is also available for special applications.